NYC ACMACM FABRICATION & INSTALLATION (home) Call or text (929) 209-3122 Free estimate

Panel installation · Install-only or full scope

Field installation of ACM wall panels in NYC

Our own crews set sub-framing, check barriers, and hang composite and plate panels to tight reveal lines across all five boroughs—whether we fabricated the trays or your vendor shipped them.

Call or text (929) 209-3122

Book spring work now. Winter assessments and estimates available.

Updated November 2026

AI-generated illustration: a crew hanging metal wall panels from a pipe scaffold

AI-generated illustration

AI-generated illustration: crew on supported pipe scaffold hanging ACM panels onto aluminum extrusions over a weather barrier

Short answer

NYC ACM Panels installs aluminum composite and single-skin plate panels across Manhattan, Brooklyn, Queens, the Bronx, and Staten Island using our own insured field crews. Many general contractors hire us strictly for installation of panels fabricated by others. We install sub-framing girts and clips over the weather barrier, laser-align reveals, set trim and transitions, and strip protective film at punch.

Key facts

Service area
All five boroughs of New York City: Manhattan, Brooklyn, Queens, the Bronx and Staten Island.
Season
Panel installation runs most of the year. Sealant joints and barrier work are done on dry, frost-free surfaces.
Who does the work
Our own crews, from The Dom Construction Group LLC.
Insurance
General liability, umbrella and workers' compensation insurance; certificates on request.
Estimates
Free. Start with 3–5 photos by text, or use the form.
Reply
We reply within one business day, Monday to Friday.

Field sequence from bare sheathing to peeled film

Disciplined layout at the backup wall is what makes flat composite panels read straight from the sidewalk.

  1. Substrate and barrier verification

    We inspect sheathing, air-water barriers, window flashings, and rough openings against the shop drawings before framing starts.

  2. Laser layout, clips, and girts

    Thermally broken brackets, Z-girts, or rail tracks are anchored and shimmed plumb over continuous insulation to true laser planes.

  3. Hanging panels to control lines

    Crews set trays in sequence, holding uniform reveal widths across corners, mullions, canopies, and parapet transitions.

  4. Joints, trims, and film removal

    Wet-seal silicone or dry-joint splines and perimeter flashings are completed, protective film comes off, and we walk punch.

Install-only labor for vendor-supplied panel packages

Many New York City general contractors, construction managers, and developers buy fabricated composite trays directly from an architectural panel manufacturer or out-of-state shop, then need a dedicated local facade subcontractor to put the package on the wall. Install-only contracts are a primary service for our crews across all five boroughs.

Before crates hit the site, we walk the substrate and compare field measurements against the approved shop drawings—checking rough window openings, steel canopy framing, parapet curbs, and masonry edges so discrepancies get flagged before erection starts. When you pair field labor with our panel fabrication, shop and site coordination sit under one team; when panels ship from your vendor, we coordinate phased delivery drops to match floor-by-floor or elevation-by-elevation progress.

Sub-framing, shimming, and thermal clip layout

Flat ACM panels are unforgiving over out-of-plane framing. If steel studs, concrete spandrels, or CMU backup walls bow in and out, unshimmed rails will twist the panel returns and throw reveal widths off line. Over the inspected substrate and waterproofing air-water barrier, our crews establish laser control planes and set Z-girts, hat channels, extruded aluminum tracks, or clip-and-rail brackets shimmed dead plumb and straight.

On insulated commercial walls, thermally broken fiberglass or isolative aluminum clips carry dead load and wind load through continuous mineral wool or rigid board insulation back to structure without compressing the insulation layer. Fastener types, clip spacing, and expansion joints follow the project's engineered shop drawings—and where code mandates an NFPA 285 tested wall assembly, match the exact framing and insulation components specified on the approved drawings.

Reveal control at corners, storefronts, and parapets

Clean composite facades depend on consistent joint geometry—roughly half-inch caulked joints on wet-seal systems or uniform shadow-line reveals on rainscreen systems—aligned cleanly with storefront mullions, louver frames, and window heads. Installers verify directional arrows on metallic PVDF finishes before hanging each tray so light reflection stays uniform across the elevation.

Beyond flat wall modules, we install folded inside and outside corners, window jamb and head returns, soffit drip edges, column wraps, heavy-duty single-skin plate panels at street level, parapet copings, and perimeter sealant transitions where metal meets glass, brick, EIFS, or stucco.

Supported scaffold, boom lifts, and NYC site coordination

Tight urban frontages and active commercial entries demand orderly access and clean housekeeping. The Dom Construction Group LLC owns supported pipe and frame scaffolding erected by our own crew, and we also install from boom lifts and scissor lifts where slab ratings, street permits, and setbacks suit.

Field crews work in hard hats and harnesses, protecting the factory peel-off film on every panel face until overhead masonry, glazing, or sealant work wraps up. Once joints and flashings are complete, we strip the protective film cleanly and walk punch with your site superintendent. Send your drawings through our bid request page or call (929) 209-3122.

AI-generated illustration: metal girts and clips over an air and water barrier, ready for panels

AI-generated illustration

AI-generated illustration: sub-framing girts and thermally broken clips mounted over continuous insulation and an air-water barrier.

Field installation questions

What happens behind ACM panels before the trays are hung?

Over structural sheathing or masonry, the wall typically receives a continuous air and water barrier, metal flashings at rough openings, exterior continuous insulation where detailed, and shimmed sub-framing girts, hat channels, or thermally broken clip-and-rail brackets. Getting those rails plumb and coplanar with lasers keeps the finished panel faces flat.

How do thermally broken clips help on insulated commercial walls?

Running continuous steel Z-girts straight through exterior insulation creates a thermal bridge that conducts heat and cold across the envelope. Thermally broken clips use fiberglass bodies or isolative pads to stand the outer aluminum rail off the backup wall, carrying structural wind loads while letting continuous mineral wool insulation perform properly.

How do your crews access mid-rise elevations in New York City?

Access is planned around building geometry, street frontage, and the general contractor's logistics plan. The Dom Construction Group LLC owns supported pipe and frame scaffolding set by our own crew, and we also install panels from boom lifts and scissor lifts where slab capacities, setbacks, and permits allow.

When should the peel-off protective film come off installed ACM panels?

Protective film stays on during panel hanging and joint sealing to shield the PVDF finish from mortar drips, dust, and tool marks, though edges are pulled back at wet-seal joints before caulking. It should be peeled promptly once overhead trades clear the area so prolonged UV exposure does not bake adhesive onto the panel.

What if the existing backup wall is out of plumb before panels go on?

Concrete spandrels, CMU walls, and older steel stud framing frequently vary across an elevation. During layout, our installers shoot laser reference planes and shim sub-framing clips and girts within engineered tolerances so the finished ACM modules hang flat and align cleanly at corners, window jambs, and storefront heads.

Get an install-only or full-scope field quote

Send architectural elevations, wall sections, and your vendor's shop drawings if panels are already ordered.

Rather text? Text photos to (929) 209-3122

What are you seeing? (optional)
Add details (optional)
Property (optional)
How soon? (optional)
Best way to reply (optional)
Photos (optional, up to 5)

Add 3–5 photos: one close-up and one of the whole wall. We shrink them before sending.

    required. We reply within one business day, Monday to Friday. We use your details only to reply to this request. Privacy

    Rather text?

    (929) 209-3122

    Call or text Monday–Friday, 7 AM–5 PM.

    Systems and access we handle on site

    Panels arriving on site and need a facade crew?

    Book spring work now. Winter assessments and estimates available.