NYC ACMACM FABRICATION & INSTALLATION (home) Call or text (929) 209-3122 Free estimate

Waterproofing · Five Boroughs

Facade waterproofing, barriers and sealants in NYC

Air and water-resistive barriers behind wall panels, low-modulus silicone sealant joints, transition flashings and breathable coatings for commercial and mixed-use buildings.

Call or text (929) 209-3122

Book spring work now. Winter assessments and estimates available.

Updated November 2026

AI-generated illustration: metal girts and clips over an air and water barrier, ready for panels

AI-generated illustration

AI-generated illustration: air and water barrier with sub-framing girts behind commercial wall panels

Short answer

We install air and water-resistive barriers, sheet and liquid transition flashings, silicone panel-joint sealants, and breathable wall coatings on New York City commercial and mixed-use facades. General contractors and owners hire us either alongside our ACM and plate panel work or as a standalone waterproofing package. Send drawings or wall photos for free pricing.

Key facts

Service area
All five boroughs of New York City: Manhattan, Brooklyn, Queens, the Bronx and Staten Island.
Season
Panel installation runs most of the year. Sealant joints and barrier work are done on dry, frost-free surfaces.
Who does the work
Our own crews, from The Dom Construction Group LLC.
Insurance
General liability, umbrella and workers' compensation insurance; certificates on request.
Estimates
Free. Start with 3–5 photos by text, or use the form.
Reply
We reply within one business day, Monday to Friday.

Air and water barriers behind commercial panel walls

Every rainscreen and wet-seal facade depends on the weather plane behind the cladding. Before sub-framing girts or continuous insulation go on the wall, our crews apply fluid-applied or sheet air and water-resistive barriers over exterior sheathing in accordance with the project specifications.

Details around rough openings and structural penetrations decide whether that membrane holds up under wind-driven rain. We detail window sills, jambs, headers, relief angles, structural outriggers, and sub-framing clip penetrations using compatible transition membranes, liquid flashings, and detail tapes required by the specified assembly. When an architect's drawings require an NFPA 285 tested wall assembly with FR-core ACM panels, we follow the specified barrier, insulation, and detailing components without substitution.

Silicone panel joints and facade transition sealants

On face-sealed composite walls, roughly 1/2-inch panel reveals rely on clean joint geometry: closed-cell or soft backer rod set to uniform depth and low-modulus silicone sealant tooled cleanly without three-sided adhesion. During panel installation, our mechanics mask adjacent fluoropolymer PVDF faces or work carefully along the factory protective film so fresh silicone never smears onto finished panels.

Just as important are perimeter joints where metal wall panels or plate panels meet neighboring materials:

  • aluminum storefront, curtain wall, and louver frames
  • brick masonry, cast stone, and precast concrete bands
  • adjacent EIFS or stucco wall planes
  • coping joints, expansion joints, and underside canopy soffits

On occupied commercial and mixed-use buildings across Manhattan, Brooklyn, Queens, the Bronx, and Staten Island, we also cut out split, hardened caulk joints, grind or solvent-clean substrates as required, prime non-porous or porous edges where specified, and install new backer rod and architectural sealant.

Sheet-metal flashings and breathable wall coatings

Sealant alone cannot stop water where metal flashing was left out. Alongside barrier and joint scopes, we install drip caps, head flashings, sill pans, kick-out diverters, reglet flashings, and parapet cap seals that push water clear of the wall face.

For masonry, concrete, stucco, and EIFS elevations showing hairline crazing or weathering, we apply breathable architectural wall coatings that shed rain while letting trapped interior vapor escape rather than blistering the film. Before any coating goes down, we power-wash or hand-clean chalk and dirt, sound the surface for loose patches, repair cracks, and check moisture conditions so the finish bonds properly. Nearby Westchester and Nassau commercial buildings are also covered by arrangement.

One exterior envelope crew from barrier out to panel

Splitting the air barrier, sub-framing, cladding, and perimeter caulking across three subcontractors creates schedule handoffs and finger-pointing whenever a window head or transition leaks. NYC ACM Panels is part of The Dom Construction Group LLC, serving the five boroughs from our Albany office. Our field team has about 19 years of experience in EIFS, stucco, masonry, and coatings, backed by company-owned scaffolding, general liability, umbrella, and workers' compensation insurance, and registration on the New York State public work contractor registry.

General contractors, developers, and property managers can include facade waterproofing inside a panel bid or price it standalone. Upload drawings on our bid request page or call (929) 209-3122.

Joint and barrier failures we correct on city facades

Where water bypasses cladding and perimeter transitions on commercial walls.

Split or cohesive-failed panel caulk

Open gaps along wet-seal panel reveals or window perimeters.

Usually means
Aged urethane sealant, missing backer rod causing three-sided adhesion, or unprimed metal returns.
What we do
Cut out old caulk cleanly, solvent-wipe returns, set proper backer rod and tool low-modulus silicone.

Leaks at storefront and masonry transitions

Interior staining where ACM or plate bands meet glass frames or brick.

Usually means
Discontinuous air barrier tie-in or omitted sheet-metal head and jamb flashings behind the joint.
What we do
Open transition trim, tie compatible membrane flashing into the rough opening, and re-seal the perimeter.

Unsealed sub-framing clip penetrations

Moisture tracking along fasteners into exterior sheathing.

Usually means
Girts and brackets anchored through the barrier without detail sealant or thermal-pad gaskets.
What we do
Detail clip footprints and fastener penetrations with specified liquid flashing or compatible sealants.

Blistered paint on adjacent masonry or stucco

Peeling film next to metal coping caps and spandrel bands.

Usually means
Non-breathable paint trapping wall moisture fed by open parapet or coping joints.
What we do
Seal the coping entry point, strip loose film, patch substrate cracks and apply a breathable facade coating.
AI-generated illustration: a wet-seal ACM joint with backer rod and silicone sealant

AI-generated illustration

AI-generated illustration: clean silicone wet-seal reveals and perimeter transitions on a commercial facade

Facade waterproofing and panel sealant questions

Why include the air and water barrier in the wall panel subcontract?

Putting the air and water-resistive barrier, sub-framing penetrations, and exterior panels under one subcontractor eliminates trade handoffs over who sealed clip fasteners, rough openings, and transition flashings. When the same crew applies the membrane, details window perimeters, mounts girts, and hangs the cladding, substrate readiness and penetration sealing happen in one continuous field sequence.

What sealant goes into wet-seal ACM and metal panel joints?

Commercial wet-seal metal panel joints typically use low-modulus neutral-cure architectural silicone installed over properly sized backer rod so the sealant bonds only to the two opposing panel returns. Silicone resists ultraviolet exposure, extreme heat on dark fluoropolymer coatings, and winter contraction far better than standard urethane caulks, though exact product selection always follows Division 07 specifications.

Do open-joint rainscreen facades still require sealant and flashing work?

Yes. Even when field panel reveals remain open for cavity drainage, a rainscreen facade relies on continuous air and water barrier detailing behind the cladding, sheet-metal or liquid flashings at rough openings and shelf angles, and perimeter sealant joints where panel terminations meet storefront frames, masonry returns, roof copings, or soffit penetrations.

How do breathable facade coatings differ from ordinary exterior paint?

Ordinary film-forming paints can trap interior moisture vapor behind the surface on masonry, cement stucco, or EIFS walls, leading to blisters and peeling after freeze-thaw weather. Breathable architectural coatings are formulated to shed wind-driven rain on the outside while remaining vapor-permeable so residual moisture inside the wall substrate can dry outward safely.

How do you prevent silicone staining on finished PVDF panel faces?

Clean panel joints start with masking finished edges or keeping the factory protective film folded back cleanly along the return flange while caulking. Mechanics tool joints with dry spatulas rather than soapy water solutions that smear residue onto fluoropolymer coatings, and verify non-staining silicone formulations whenever specifications call for sensitive metallic, matte, or adjacent stone surfaces.

Request pricing on barriers, sealants or wall coatings

Send architectural sections, joint schedules or exterior wall photos for a free commercial estimate.

Rather text? Text photos to (929) 209-3122

What are you seeing? (optional)
Add details (optional)
Property (optional)
How soon? (optional)
Best way to reply (optional)
Photos (optional, up to 5)

Add 3–5 photos: one close-up and one of the whole wall. We shrink them before sending.

    required. We reply within one business day, Monday to Friday. We use your details only to reply to this request. Privacy

    Rather text?

    (929) 209-3122

    Call or text Monday–Friday, 7 AM–5 PM.

    Cladding scopes tied into facade waterproofing

    Need one crew for the air barrier, panels and caulk?

    Book spring work now. Winter assessments and estimates available.