Short answer

Dry-joint and open-joint ACM rainscreens shed bulk rain at the outer aluminum panel while letting any moisture that passes the reveal drain and dry inside a ventilated cavity behind the cladding. Using perimeter extrusions, hook-on clips, and girts over an air and water barrier, we fabricate and install rainscreen packages across New York City strictly to approved shop drawings.

Key facts

Service area
All five boroughs of New York City: Manhattan, Brooklyn, Queens, the Bronx and Staten Island.
Season
Panel installation runs most of the year. Sealant joints and barrier work are done on dry, frost-free surfaces.
Who does the work
Our own crews, from The Dom Construction Group LLC.
Insurance
General liability, umbrella and workers' compensation insurance; certificates on request.
Estimates
Free. Start with 3–5 photos by text, or use the form.
Reply
We reply within one business day, Monday to Friday.

How drained and pressure-equalized cavities manage weather

Rather than counting on exposed silicone sealant to block every drop of wind-driven rain, a rainscreen ACM panel wall separates the exterior cladding from the primary weather barrier with a drained, ventilated air cavity. The outer aluminum composite trays deflect bulk rain while leaving clean dry-joint, spline-baffled, or open-joint reveals between modules.

Any small amount of water that passes an unsealed reveal enters the air space behind the panel, runs down the surface of the continuous waterproofing air and water barrier, and exits through weeped flashings at base tracks and floor-line breaks, while convective airflow dries residual moisture. Pressure-equalized rainscreen designs take this further by compartmentalizing the cavity so internal air pressure equalizes rapidly during wind gusts, neutralizing the pressure drop that would otherwise pull water inward through open joints.

Perimeter extrusions, hook-on clips, and panel removal

Rainscreen panels start in panel fabrication, where CNC-routed returns are fitted with continuous aluminum perimeter extrusions, concealed back stiffeners, and slotted hook-on clips or slide blocks. During panel installation, our crews laser-align vertical carrier rails or sub-framing girts and set fixed and sliding attachment points so each aluminum tray can expand and contract thermally without binding or warping.

Hook-on extrusion systems also offer a major lifecycle benefit for New York City building owners and managers: when the specified system is detailed for non-sequential removal, an individual ground-floor or lower-elevation tray damaged by street impact can often be unhooked and replaced without cutting perimeter caulk or stripping neighboring courses above it.

Air barriers, continuous insulation, and fireblocking details

Because a rainscreen leaves its outer joints open or gasketed without face sealant, the backup assembly performs the true air-sealing and thermal work. Over exterior gypsum sheathing or concrete masonry, the air and water barrier must be continuous, tightly detailed around window rough openings and clip penetrations, and rated for ultraviolet exposure wherever open reveals let daylight hit the cavity.

Continuous exterior insulation—typically semi-rigid mineral wool on NYC commercial buildings—sits over the barrier between thermally broken brackets and girts. Where NYC building code and project specifications require an NFPA 285 tested exterior wall assembly and horizontal or vertical cavity fireblocking, mineral-filled FR-core ACM (or noncombustible A2-type cores and single-skin plate panels), rail alloys, and insulation types must match the tested assembly selected by the architect. We build strictly to the approved architectural drawings and engineered shop drawings.

Why architects specify dry-joint panels on NYC mid-rises

Dry-joint and open-joint rainscreens stay cleaner on busy city avenues because there are no silicone beads in the panel-to-panel reveals to attract airborne soot or leach oil streaks onto metallic PVDF coatings. Deep shadow lines also hold crisp grid geometry across multi-story elevations and tie neatly into curtain wall, masonry, EIFS, and stucco.

Many projects pair drained rainscreens on upper walls with wet-seal systems on entrance canopies and sign bands below. Review core and coating basics at what ACM is, or send your bid documents through our bid request page.

Ventilated cavity framing and dry-joint reveals

AI-generated illustration: metal girts and clips over an air and water barrier, ready for panels

AI-generated illustration

AI-generated illustration: thermally broken clips and girts creating a ventilated air space over continuous insulation
AI-generated illustration: finished metal panel facade on a city building

AI-generated illustration

AI-generated illustration: finished mid-rise commercial facade with crisp dry-joint ACM panel modules

Rainscreen ACM system questions

Doesn't an open-joint rainscreen let rain get behind the ACM panels?

Only a small fraction of wind-driven water passes through open or baffled reveals; most rain sheds right down the outer aluminum face. Any moisture that enters the ventilated air cavity runs harmlessly down the continuous air-water barrier behind the girts and drains out through flashing weeps while airflow dries the space.

What is the difference between a drained rainscreen and a pressure-equalized rainscreen?

Both use unsealed reveals and a ventilated drainage cavity over an air barrier. A standard drained-and-back-ventilated rainscreen relies on gravity drainage and airflow, whereas a pressure-equalized rainscreen adds compartmentalized cavity baffles so internal air pressure matches wind gusts rapidly, stopping pressure differentials from drawing water inward.

Can individual damaged panels be replaced on a clip-and-rail rainscreen?

Depending on the exact extrusion and hook-on clip profile specified on the shop drawings, many dry-joint rainscreen systems allow individual trays to lift off their carrier pins without cutting perimeter sealant. Progressive interlocking systems require sequential removal, so demountability depends on the specific rail hardware detailed for the building.

What kind of air and water barrier goes behind an open-joint ACM facade?

Because open reveals expose narrow strips of the cavity to sunlight and weather, specifications typically call for a continuous fluid-applied or sheet air-water barrier—often black in color so it disappears visually behind shadow reveals—paired with UV durability ratings suited for open-joint rainscreen exposure.

How does NFPA 285 affect ACM rainscreen assemblies in New York City?

Where NYC building code triggers NFPA 285 for exterior walls containing combustible components, every element of the rainscreen—panel core (such as mineral-filled FR core), air-water barrier, exterior insulation, sub-framing girts, and cavity fireblocking—must conform to a tested assembly specified by the architect on the approved drawings.

Send rainscreen drawings and specs for a quote

Include Section 07 42 00 specs, wall sections, and elevations for fabrication, installation, or both.

Rather text? Text photos to (929) 209-3122

What are you seeing? (optional)
Add details (optional)
Property (optional)
How soon? (optional)
Best way to reply (optional)
Photos (optional, up to 5)

Add 3–5 photos: one close-up and one of the whole wall. We shrink them before sending.

    required. We reply within one business day, Monday to Friday. We use your details only to reply to this request. Privacy

    Rather text?

    (929) 209-3122

    Call or text Monday–Friday, 7 AM–5 PM.

    Related panel and barrier pages

    Pricing a mid-rise rainscreen facade in the five boroughs?

    Book spring work now. Winter assessments and estimates available.